Potentiostat/Galvanostat/ZRAs

Click here for Potentiostat Specifications


We are pleased to announce the Series G 300and the Series G 750™ Potentiostats.  The Series G Potentiostats were engineered to meet the requirements of the Reduction of Hazardous Substances (RoHS) regulations of the European Union.  Looking toward the future, we made sure that all the components in the Series Gs were the most modern available, guaranteeing availability while optimizing performance.

These instruments are installed in the PCI slots of your Windows computer. The  Series G 300 and Series G 750 feature current resolution down to 1 fA and 2.5 fA, respectively, and share a voltage resolution capability of 1 µV.  In addition, they have a current output of 300 mA and 750 mA, respectively.  



Gamry also designs and manufactures the Reference 600 Potentiostat/Galvanostat/ZRA, a high-performance USB-controlled instrument.  The Reference 600 is blazingly fast, whisper quiet, and talks to your computer through a USB port.

All Gamry Potentiostats use Sub-Harmonic Sampling and Digital Signal Processing techniques to make EIS measurements up to 1013 ohms over a frequency range of 10 µHz to 1 MHz.

A Bipotentiostat can be easily configured from two Gamry Potentiostats.  No hardware modification is required and the Potentiostats can be instantly converted to stand-alone Potentiostats.

The ability of a potentiostat to accurately perform EIS is a serious technical issue, because the potentiostat must make this measurement over a wide range of frequencies on samples with a wide range of impedances.  Gamry publishes an Accuracy Contour Plot for each of our Potentiostats so you can evaluate their AC performance and compare them to other commercial potentiostats.

Choosing a potentiostat-software combination is relatively simple.  Every Gamry Potentiostat  works with every Gamry software application package.  Choose your Potentiostat based on the current levels, scan rates in CV, and/or electrochemical impedances you expect to encounter during your measurements.  Choose your software based on the electrochemical techniques you plan to use to accomplish your application.  If your application doesn't use a standard electrochemical technique, give us a call and describe your experiment.  We can tell you quickly if we can use Open Source Scripting to create a custom script to accomplish your task.

 

Output
Current
Current
Resolution
Current Ranges
(decades/range)
Compliance
Voltage
Reference 600 ± 600 mA 0.018 fA* 11/ (±60 pA - ±600 mA) ±20V
Series G 300 ± 300 mA 1 fA* 9 / (±3nA - ±300mA) ±20V
Series G 750 ± 750 mA 2.5 fA* 9 / (±7.5nA - ±750mA) ±12V
* x100 gain


Click here for detailed specifications for Gamry Potentiostats.


Gamry Software uses the Framework and Echem Analyst as our software platform.  This provides a common look-and-feel to our software to lower the learning curve.  As a result, moving from one application to another is easy.  The Framework and Echem Analyst are the basis for Open Source Scripting, our solution to the problem of inflexible electrochemical software.

Use the chart above to find the instrument that meets your application requirements.  If you still have questions or are unsure which instrument is right for you, contact an electrochemist at Gamry  regarding your application requirements.


 

 

Standard Features

  • Earth-Ground Isolation - Gamry Potentiostats are designed for real-world applications.    All Gamry Potentiostats are fully isolated (electrically) from the host computer's chassis ground, allowing normal operation with earth-grounded cells.  As a result, Gamry Potentiostats function very well (and very safely!) in autoclaves, with strain rate testers, and with grounded structures.  Caution: only one electrode in the cell can be grounded.
  • Portability - All Gamry Potentiostats were designed to be used in the field as well as in a laboratory environment.  The Reference 600 connects directly to a Notebook Computer with the USB interface.  Gamry Series G Potentiostats can be used with our eStation Portable Electrochemistry System and controlled with a Notebook Computer.  
  • Internal EIS Capability  -  On-board electronics allow Sub-Harmonic Sampling for EIS measurements from 10 µHz to 1 MHz for the Reference 600 and 10 µHz to 300 kHz for the Series G Potentiostats.
  • Multiplexed Potentiostats - Up to eight Gamry Potentiostats can be controlled from one computer in a MultEchem System.  The Potentiostats can be operated simultaneously and independently of each other!  For sequential measurements, use an ECM8 Multiplexer.  Unlike competitve multiple-potentiostat systems, the MultEchem uses the same software as our single Potentiostats, so you don't have to familiarize yourself with new software. 
  • Small Footprint - Gamry does not manufacture BIG Potentiostats because our Engineers can design compact ones.  Your bench space is valuable real estate.  The Reference 600 occupies a 10 cm x 30 cm footprint.  A Gamry Series G Electrochemistry System occupies the same bench area as the computer to conserve space.  The performance and reliability of a potentiostat is not proportional to the volume or weight of the potentiostat!  In most cases, however, the price is proportional to the volume or weight of the potentiostat!  Smart electrochemists use Gamry.
       
  • Innovative Engineering - Gamry's modern electronic design and extensive use of surface mount technology packs a lot of capability onto a small area.  
     
  • Current Interrupt and Positive Feedback iR Compensation -  No need to rig your cells with supporting electrolyte or geometric modifications anymore.  Gamry Potentiostats and their controlling software use control loop algorithms to accurately measure and correct for uncompensated resistance. The PHE200 uses EIS to measure the uncompensated resistance!
  • Auxiliary I/O - A Gamry Potentiostat communicates easily with the outside world.  All Gamry Potentiostats allow you to control additional equipment via additional I/O interfaces.

    1 Auxiliary Input for an external signal (e.g., thermocouple), saved with the data file.
    1 analog output for cell Potential 
    1 analog output for cell Current
    4 digital inputs
    4 digital outputs
    1 external signal generator input for fast CV
  • Two-Year Warranty - Every Gamry Potentiostat arrives at your lab with a two-year guarantee of reliable operation...at no extra charge!
       

 

Computer requirements

 

Systems Information

The Reference 600, Series G 750, and Series G 300 are used with Gamry Software.   Potentiostats are shipped with the  Gamry Framework, Gamry Echem Analyst, a Universal Dummy Cell 3, a Hardware Installation Manual, a Quick-Start Guide, one standard cell cable, and a Gamry Mouse Pad. Special cables, cells and other accessories are available at extra cost. These Potentiostats are protected by a two-year factory service warranty.  

Computers and computer accessories are subject to the computer vendor's warranty.  Gamry Instruments can also supply complete systems including the items above and system software installed in a desktop or a notebook computer.  Custom computer configurations, software, training, and installation are available by special order.  Contact us for further details on these systems. 

 

Home | Products | App Notes | Sales | Contact | News | Support | Search

Batteries | Fuel Cells | Corrosion | Paints & Coatings | Physical Electrochemistry


Gamry Instruments © 1997-2008
  